SMART BATTERY POWERED DATA LOGGERS FOR FLOW, LEVEL, etc.

WaMSS battery powered Smart loggers measure flow, level, etc. in integrated web-based Remote Monitoring or Water Demand Management solutions.

Smart battery powered loggers

WaMSS Smart Logger Specifications

Picture1Picture2

Flow, Level, Pressure

Logger

Multi Purpose

Logger

Model:

FLP2

MP2

Pulse input (flow or other digital input).

·         Selectable relay debounce function.

·         Maximum pulse frequency: 30Hz without debounce, or 10 Hz with debounce.

·         Automatically operates in active mode (pulse source provides voltage) or passive mode (logger provides voltage).

·         Pulses are flow totalized and logged (i.e. flow quantity, for example m3/hr, as well as number of pulses).

 

 

 

1

 

 

 

2

Analogue input (pressure, level or other parameters).

·         4-20mA with sleep function for power conservation.

·         Internal switch selects active mode (where the sensor provides power) or passive mode (where the logger provides power).

1

3

Common Specifications:

Power Supply:

·           Battery power: Lithium ion, non-rechargeable.  Battery life: minimum 3 years at 15 minute sampling interval and 24 hour transmitting interval.

·           External Power Supply: 12 – 24V DC, 3A burst current, auto changeover to battery.

Every data record is date and time stamped and contains both engineering unit and engineering value for every measurement.  This avoids confusion.

Mini USB port for logger configuration.

Logger memory capacity: more than 3 years capacity based on all inputs and 15 minute sampling interval.

Logged data is sent by built-in GSM modem via GPRS and FTP or e-mail.

(GSM: 900/1800MHz, GPRS: Class 10).

“Swipe to send GPRS” function. (Causes non-contact data send).

Integrates seamlessly with the WaMSS Scada.

Sends approximate GPS coordinates of logger location.

Sends SIM card ICCID and cell LAC and CID numbers.

Housing: Polycarbonate flameproof enclosure – IP67.

Data logging interval: selectable from 1 minute to 24 hours.

Data Transmission Interval: selectable from 15 minutes to 24 hours.

Real Time clock synchronized to GSM network.

Logged data can be downloaded to a pc by cable.

Operating temperature: -10 to 60°C.

Alarms: High and low alarms.  SMS and email and logged data transmission on inputs going into and out of alarm.

Remotely programmable by SMS.

Include intuitive Configuration Software for your pc.  Connect via standard mini USB cable.

Manufactured and supported in South Africa.